• Phone: +86-25-8619-6015

Bladder Scanner Z5

Product Advantage

  • Probe specification: 2.5MHz 3D mechanical sector scanning, sector scanning angle 120°
  • Volume measurement range: 0 ml ~ 999 ml
  • Volume measurement accuracy: ± 7.5%
  • The volume measurement results are displayed in milliliters (ml).
  • Scanning depth: ≥160 mm
  • Qr code information of patients will be displayed after scanning
  • There is a scan button on the screen, more convenient.
  • There are arrows on the screen to guide the probe in the direction of movement.
  • Store 1000 cases with store and print function
  • Synchronize patient information to the host computer
  • Interface multi-color display

Application Technology

  • The device uses a 3D mechanical sector scanning probe to perform ultrasound detection of the bladder.
  • The ultrasound imaging principle is used to measure the bladder volume through the abdominal body surface.
  • The use of the product is not affected by bladder occupying lesions and can effectively identify the bladder wall.

Function Display

  • Probe specification: 2.5MHz 3D mechanical sector scanning, sector scanning angle 120°
  • Volume measurement range: 0 ml ~ 999 ml
  • Volume measurement accuracy: ± 7.5%
  • The volume measurement results are displayed in milliliters (ml).
  • Scanning depth: ≥160 mm
  • Store 1000 cases with store and print fuction
  • Synchronize patient information to the host computer
  • Interface multi-color display
  • Non-invasive and immediate detection of bladder volume, no need for professional ultrasound doctors, suitable for use in various departments.
  • It can be used as a daily care device for the ward to reduce the urinary tract infection rate associated with the catheter (CAUTI),
  • In the pelvic floor radiotherapy, monitor the bladder capacity to ensure accurate radiotherapy at the pelvic floor.

Applicable Scenario

  • Evaluation of bladder function before and after gynecological pelvic floor surgery
  • Evaluation of various urinary diseases, urinary management, bladder function monitoring
  • Rehabilitation nursing of patients with neurogenic bladder, spinal cord injury and stroke patients, to help assess the recovery of bladder function.
  • Before the implementation of intermittent catheterization, the measurement of bladder capacity and bladder pressure to set the catheterization time is conducive to the recovery and reconstruction of bladder function.
  • Diagnose different types of urinary incontinence and dysuria, and determine the diagnosis and treatment plan.